Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Application: | Construction, Overhead, Underground, Industrial, Power Station, Telecommunication, Computer, Car |
| Voltage: | Low and Medium Voltage Cable |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Pool Robotic Cleaner Tether 2 Core Power Wires Rov Floating Cable Power Cable Flexible Cable Underwater Power Cable
| product code |
Commodity name | Specification scope | Contructure of shield layer | Components resistant and filler |
Sheath material |
| PFC9980-P | Underwater power supply buoyancy cable |
0.75-16.0mm2 (2 cores-5 cores) |
AL+Braid | Kevlar braid and filling | PUR foam |
| PFC9980-K | underwater control buoyancy cable |
0.35~2.5mm2(2 cores -61 cores) | AL+Braid | Kevlar braid and filling | PUR foam |
| PFC9980-TX | underwater communication buoyancy cable |
Ф0.51mm(2P.4P.8P) | Individulally screen+BraidTC+Overall Screen | Kevlar braid and filling | PUR foam |
| PFC9980- ROV |
Underwater Video Surveillance Buoyancy Cable |
0.22-0.35mm2(2P.4P.8P) | Kevlar filing | PUR foam | |
| PFC9980-D | Underwater multi-pair buoyancy cable |
0.22-10.0mm2(2P-50P) | Individulally Screen+BraidTC+Overall Screen | Kevlar braid and filling | PUR foam/rubber |
| PFC9980- PK |
Underwater power and control buoyancy cables |
Power Supply:0.75-16.0mm2(Symmetrically twisted) | AL+Braid | Kevlar braid and filling | PUR foam/rubber |
| Control Cable:0.35-1.5mm2(Symmetrically twisted) | |||||
| PFC9980-JD | Underwater umbilicalbuoyancy cable | Power supply:0.75-16.0mm2(Symmetrically twisted) | Kevlar double weaveKevlar rope filling | PUR inner sheath+PURfoam+XLPE outer sheath | |
| RS485 cable (Symmetrically twisted) |
AL+Braid | ||||
| Fiber Optic Cable (SymmetricallyTwisted) | Steel tape armor | ||||
| 18AWG video cable (symmetrically twisted) |
AL+Braid |

| Brand | LINKE | Cross Section (mm²) | 0.01-500mm² |
| Wire Gauge (AWG) | [e.g., 24AWG, 28AWG] | Conductor | Tinned Copper /bare copper, based on client's requirements |
| Insulation material | PVC/TPU/Silicone rubber/PE/PP/XLPE/Nylon/other | Jacket Material | [PVC/PU/Rubber/Braid/etc.] |
| Certifications | RoHS/REACH/UL/CE/IP68/etc | Custom Length | [e.g., 1m, 3ft, 5m ±5% tolerance] |
| Cable Type | [Medical/Power/Audio/Coaxial/Electrical/Automotive/Energy storage//etc.] | Shielding | [Shielded/Unshielded/Braid Shield] |
| Impedance | [e.g., 75Ω (for coaxial cables)] | Printing/Logo | [Text/Label/Logo, max. 20 characters] |
| Bend Radius | [e.g., ≥5× cable diameter] | Current Rating | [e.g., 5A] |
| Voltage Rating | [e.g., 30V AC/DC] | Connector Material | [Gold-plated/Nickel-plated/Brass/etc.] |
| Connectors | [e.g., USB Type-C, 3.5mm Jack, RJ45] | Jacket | XLPE or PE or PVC RUBBER |
| Delivery Time | 7-14 days after confirming the order | Colors | [Black/White/Red/Custom Pantone/etc.] |
| temperature | Minus-70ºCto 350ºC(-70ºC ~ 350ºC) | Package | Roll/box/plate/Custom |
| Supporting Services | \multicolumn {3}{l}{custom cable, end to end solutions, including precise cutting, crimping and installation of lugs (specify material,e.g.,copper/nickel plated) |

Independent Laboratory • Complete Testing Equipment • Full Quality Control
| No. | Test Item | Test Condition | Test Requirement | Test Data | Result |
| 1 | Structure Inspection | 1. Comply with wire size table2. Minimum thickness ≥ 80% of average thickness | Comply with wire size table | Refer to test record | Pass |
| 2 | Thermal Shock | Wind the sample on an iron rod of specified size, place in an aging oven at specified temperature for 1 hour, cool the sample to room temperature for at least 30 minutes, then observe the sample | No cracks on the sample surface | No cracks | Pass |
| 3 | Heat Deformation | 1. Measure sample thickness (mark measurement position)2. Place sample and test fixture in aging oven for preheating at specified temperature for 1 hour3. Place sample under pressure column of test fixture for 1 hour4. Re-measure sample thickness at the same position | 1. Sample shall not be cracked by pressure column or expose conductor2. Thickness reduction ≤ 50% | Refer to test record | Pass |
| 4 | FT2 | Apply a standard flame at a height of 125mm once | 1. Flame shall not propagate along its length2. Flame shall not spread to nearby flammable materials | Refer to test record | Pass |
| 5 | Aging | 1. Take five sections of 200mm-long sheath2. Place specimens in aging oven at 158ºC for 168 hours3. After taking out specimens, place at room temperature 23±5ºC for 16 hours, then test elongation at break and tensile strength | 1. Elongation before aging ≥ 300%, elongation after aging ≥ 80% of that before aging2. Tensile strength before aging > 1.41kg/mm², tensile strength after aging ≥ 80% of that before aging | Refer to test record | Pass |
| 6 | Cold Bend | Store sample in low-temperature box at specified temperature for 4 hours, wind sample on iron rod of specified size with specified turns, complete winding within 30 seconds after sample is taken out of low-temperature box | No cracks on the sample surface | No cracks | Pass |
| 7 | Conductor Resistance | Measure resistance of one-meter core conductor with DC resistance meter | At 20ºC, resistance of 8AWG ≤ 2.23Ω/km | Refer to test record | Pass |
CNR- Appliance Wiring Material,
Extruded PVC Insulated Single,rated 105ºC,1000V,ClassI,GroupA,B,or AB, FT1 and/or FT2.
Extruded PVC Non-integral Jacketed Cable, rated 105"C, 1000V, Class I, Class or Class I/Il, Group A, B, or AB, FT1 and/or FT2.
Extruded TPU Non-integral Jacketed Cable, rated 80"C, 300V, Class I, Class or Class I/Il, Group A, B, or AB, FT1 and/or FT2
1. Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first begining to the last.
Welcome to visit us. We'll pick you up in Shenzhen.
2. How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.
3. What's your Minimum Order Quantity?
Normally 100m. However, the cable is very heavy.
You'd better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.
4. Can I get a discount?
It depends on your quantity, We can make a discount and afford the freight. Pls kindly contact us.
5. Does your company accept OEM production?
Yes, could print your company name, we even custom the quality card to promote your company